Performance Test Data

  REQUIREMENTS NOMEX®/LENZING FR PBI®/LENZING FR P84/LENZING FR
* Thermal Protection Performance (TPP)
(ASTM D4108)*
Initial (seconds)
After 5 washings (seconds)
*TPP at heat flux of 2.0 cal/cm2 * sec
20.0 Min.
20.0 Min.
28.0
42.1
31.1
40.0
24.3
25.5
After Flame
Initial (seconds)
Warp (Wales)xFill (Courses)
After 5 washings (seconds)
Warp (Wales)xFill (Courses)
2.0 Max.
2.0 Max.
0 x 0
0 x 0
0 x 0
0 x 0
0 x 0
0 x 0
Char Length
Initial (inches)
Warp (Wales)xFill (Courses)
After 5 washings (inches)
Warp (Wales)xFill (Courses)
4.0 x 4.0 Max.
4.0 x 4.0 Max
1.4 x 1.4
1.0 x .8
1.1 x 1.2
1.1 x 1.1
3.1 x 3.3
2.6 x 3.1
Melt or Drip when exposed to Flame No Melting or Dripping None None None
Thermal Shrinkage (After 5 min. @ 260° C)
Initial (%)
Warp (Wales)xFill (Courses)
After 5 washings (%)
Warp (Wales)xFill (Courses)
10 x 10 Max.
10 x 10 Max.
0 x 0
0 x 0
2.7 x 5.2
2.3 x 6.8
0 x 0
2.3 x 3.0
Washing Shrinkage
After 5 washings (%)
Warp (Wales)xFill (courses)
5 x 5 Max. 2.9 x 0 4.8 x +16.3 1.7 x 1.7

* TPP test data premised on using our COMFORT-PLUS lining.


Next Page

| PGI Home | Back to the "Web Threads" Directory | FireLine Homepage |