Performance
Test Data |
| |
REQUIREMENTS |
NOMEX®/LENZING
FR |
PBI®/LENZING FR |
P84/LENZING FR |
* Thermal Protection Performance
(TPP)
(ASTM D4108)*
Initial (seconds)
After 5 washings (seconds)
*TPP at heat flux of 2.0 cal/cm2 * sec |
20.0 Min.
20.0 Min. |
28.0
42.1 |
31.1
40.0 |
24.3
25.5 |
After Flame
Initial (seconds)
Warp (Wales)xFill (Courses)
After 5 washings (seconds)
Warp (Wales)xFill (Courses) |
2.0 Max.
2.0 Max. |
0 x 0
0 x 0 |
0 x 0
0 x 0 |
0 x 0
0 x 0 |
Char Length
Initial (inches)
Warp (Wales)xFill (Courses)
After 5 washings (inches)
Warp (Wales)xFill (Courses) |
4.0 x 4.0 Max.
4.0 x 4.0 Max |
1.4 x 1.4
1.0 x .8 |
1.1 x 1.2
1.1 x 1.1 |
3.1 x 3.3
2.6 x 3.1 |
| Melt or Drip when exposed to
Flame |
No Melting or Dripping |
None |
None |
None |
Thermal Shrinkage (After 5 min.
@ 260° C)
Initial (%)
Warp (Wales)xFill (Courses)
After 5 washings (%)
Warp (Wales)xFill (Courses) |
10 x 10 Max.
10 x 10 Max. |
0 x 0
0 x 0 |
2.7 x 5.2
2.3 x 6.8 |
0 x 0
2.3 x 3.0 |
Washing Shrinkage
After 5 washings (%)
Warp (Wales)xFill (courses) |
5 x 5 Max. |
2.9 x 0 |
4.8 x +16.3 |
1.7 x 1.7 |